350-MARITIME
The first portable emission analyzer approved for
MARPOL Annex VI and the NOx Technical Code
As air quality regulations become more strict and emission control areas become more
prevalent, it's good to have the NEW testo 350-MARITIME as your emission testing
solution. Built to meet the demands of maritime conditions, the testo 350-MARITIME
measures O2, CO and NOx more easily and less costly than other methods available.
The perfect analyzer to test exhaust gas emissions subject to MARPOL Annex VI and
the MEPC.103(49) protocol guidelines.
Reference method accuracy at a fraction of the price, all contained, convenient, rugged
transport case perfect for testing marine applications. The testo 350-MARITIME will
make your emission testing and reporting quick, easy, and affordable.
Emission Analyzer
testo 350-MARITIME
Fitted with: O2, CO,
CO2-(IR), NO and NO2,
thermoelectric sample gas
cooler, rechargeable
battery pack, auto
programming with 250,000
datalogging memory
Rugged
Case
With access ports
& integrated
wheels and
handle for easy
transport
Pre-filter
Mounting Flange
For gas sampling probe
Power cable with
battery clamps
For extended battery
operation
Control Unit testo
350-MARITIME
Highest Accuracy - Rugged Dependability
Years of practical experience in measuring emissions from industrial engines has
resulted in a new analyzer designed for the marine industry. High accuracy to meet
regulatory requirements. Unsurpassed portability to test anywhere, any time! Intuitive
operation for easier testing and data reporting.
The testo 350-MARITIME is a complete emission analyzer system that accurately
measures O2, CO, NOx, and CO2. The sensors, electronics, pumps, sample
conditioning system are integrated into a small compact analyzer weighing less than
10 lbs.
On-board verification in compliance
with the NOx Technical Code
The testo 350-MARITIME measures O2, CO, CO2 and NOx as a complete integrated
emission testing system applicable to the following MARPOL Annex VI requirements.
- On-board periodic & intermediate surveys using the "Direct Measurement"
and "Monitoring" method
- On-board "Simplified Measurement Method"
Simple Accurate Testing
Testing doesn't get any easier. Simply put the probe (w/ sintered filter) into the
exhaust stack and activate the pump. The emission measurements will quickly be
seen on the large back-lit display. For greater testing flexibility, use easyEmission
software to control the analyzer, view data in many formats, or print
emission reports.
Technical Data
| Parameter |
Measuring range |
Accuracy |
| °F, flue gas |
-40 up to 1832°F |
max. ±5 K |
| O2 |
0 ... 25 Vol% |
|
| CO |
0 ... 3000 ppm |
Meets and exceeds the requirements of NOx Technical Code as Type approved by GL |
| NO |
0 ... 3000 ppm |
|
| NO2 |
0 ... 500 ppm |
|
| SO2 |
0 ... 3000 ppm |
|
| CO2 (IR) |
0 ... 40 Vol% |
|
| pabs |
600 ... 1150 hPa 8.7 ... 16.68 psi |
0.0725 psi @ 72°F ±5 hPa at 22°C ±10 hPa at -5°C up to 45°C 0.14 psi @ -25°F up to 115°F |
| Storage temperature |
14 - 122°F/-10°C up to 50°C |
| Operation temperature |
41 - 122°F/5°C up to 50°C |
| Power supply |
11 ... 40 V DC or 110 ... 230 V AC 50/60 Hz buffer battery NiMH 8,4V/4,5Ah |
| Electrical power consumption max. |
40 W |
| Max. positive pressure / flue gas |
50 hPa/0.725 psi |
| Max. negative pressure / flue gas |
-200 hPa/-2.90 psi |
| Weight (system including case) |
appr. 37.47 lb./17 kg. |
| Dimensions (case) |
22 x 17.9 x 10.4 in./56.5 x 45.5 x 26.5 cm |
Class Type Approved:
Germanischer Lloyd (GL)-type approval
Certificate No. 59 488 - 08 HH subject to
MARPOL 73/78
Annex VI, NOx Technical Code and
MEPC.103(49)-guideline

Certificate No. 59 488 - 08 HH
Downloads
Literature
Brochure
– (387 KB) PDF
Accessories
Optional:
Standard ambient climate probe
(temperature and relative humidity)
Order No. 0636 9740
Connection cable to ambient climate
probe, length 4.9 ft./1.5 m
Order No. 0430 0143
* SO2-measuring on request Germanischer
Lloyd (GL) - Certificate